Keep Data Flowing

Self-cleaning disc filtration that protects your cooling towers - so your infrastructure never stops.

0
Flow interruptions. Ever.
↓40%
Lower maintenance costs
500MW
From edge site to hyperscale

When Water Stops, Data Stops

Data centers run 24/7. Cooling towers can't pause. Fouling, corrosion, and clogged filters silently degrade heat transfer until an unplanned outage brings everything down. DATA Klin breaks that chain before it starts - with self-cleaning disc filtration that runs automatically, continuously, and without interrupting your cooling flow.

What's At Stake When Water Fails?

Fouling & Corrosion

Suspended solids and biofouling clog heat exchangers, restrict flow, and degrade thermal efficiency - forcing energy-wasting overcompensation.

Heat-Related Outages

Excess thermal loads push coolant beyond safe limits, triggering automatic derating and - in worst cases - catastrophic shutdown events.

High Maintenance Costs

Manual basin cleaning, cartridge replacements, and system isolations eat into budgets and require planned - or worse, unplanned - downtime.

Water & Energy Waste

Poor heat transfer forces pumps and chillers to work harder, spiking PUE and driving up utility costs while undermining sustainability goals.

Downtime During Maintenance

Traditional filter maintenance requires flow isolation - creating dangerous cooling gaps during the very maintenance cycles meant to prevent problems.

The Only Filter Built for Data Centers

DATA Klin is the only self-cleaning, packaged disc filter series purpose-built for data center cooling towers - powered by Spin Klin™ NOVA technology. Zero flow interruptions. Zero manual intervention. Continuous protection from 0.5 MW edge sites to 500 MW hyperscale campuses.

No Downtime

Self-cleaning runs on a live sidestream loop - cooling water flow is never interrupted. Your uptime SLAs stay intact.

Corrosion Resistant

Polymeric disc pods and stainless pipework stand up to aggressive cooling tower chemistry without degrading.

Eco-Efficient

Low pressure-drop operation reduces pump energy. Backwash water integrates with your blowdown process.

Massively Scalable

Modular architecture covers 0.5 MW edge facilities to 500 MW hyperscale campuses - one consistent filtration standard.

The DATA Klin Range

Every DATA Klin system is built on the same Spin Klin™ NOVA disc technology - self-cleaning, fully automatic, and rated to 55μm as standard.

3" Spin Klin™ Nova Single

3" Spin Klin™ Nova Single

Entry / Edge - 0.5 to 5 MW

Max. flow rate
18 m³/h  (80 gpm)
Inlet / Outlet
100/76 mm  (4"/3")
4" Spin Klin™ Nova Plus Single

4" Spin Klin™ Nova Plus Single

Mid-Range - Colocation / Enterprise

Max. flow rate
55 m³/h  (240 gpm)
Inlet / Outlet
100/76 mm  (4"/3")
4" Spin Klin™ Nova Dual

4" Spin Klin™ Nova Dual

Mid-Range - Redundancy & Reliability

Max. flow rate
39 m³/h  (160 gpm)
Inlet / Outlet
127/100 mm  (5"/4")
6" Spin Klin™ Nova Plus Dual

6" Spin Klin™ Nova Plus Dual

Large Scale - Hyperscale / High Load

Max. flow rate
109 m³/h  (480 gpm)
Inlet / Outlet
127/152 mm  (5"/6")
6" Spin Klin™ Nova Plus Trio

6" Spin Klin™ Nova Plus Trio

Large Scale - Campus / AI Clusters

Max. flow rate
164 m³/h  (720 gpm)
Inlet / Outlet
150/203 mm  (6"/8")

Amiad's Patented Spin Klin™ Disc Technology

Unlike surface-only filters, Spin Klin™ NOVA discs are grooved diagonally from both sides. Stacked and compressed on a specially designed spine, they form a 3D matrix that traps particles throughout the element depth - not just at the surface. The result is greater dirt-holding capacity, longer filtration cycles, and more consistent particle capture across the full 10–400µm range.

Spin Klin disc technology process - from filter stack to disc to groove detail to 3D matrix

ISO-Verified Filtration Accuracy

  • Declared micron rating = actual measured performance
  • Verified to ISO 18471 - the world-recognised standard
  • No estimates, no overstatement
  • Consistent particle capture across 10–400μm range

Water-Efficient Backwash

  • Minimal water use per cycle
  • Integrates with existing blowdown process
  • Reduces waste and supports water efficiency targets
  • Automatic differential pressure triggering

Longer Filtration Cycles

  • 3D depth filtration captures more particles
  • Fewer backwash cycles needed
  • Less disruption to operations
  • Lower maintenance cost over time

Spin Klin™ NOVA Disc Technology

  • Diagonally grooved from both sides
  • 3D matrix traps particles throughout depth
  • Greater dirt-holding capacity
  • Patented Amiad technology

Proven Performance: ISO 18471 Verified

Amiad verifies every disc filter to ISO 18471 - the world-recognised standard for disc filtration performance. For data centers, consistent, verified filtration protects heat exchangers and cooling towers from particulate fouling that silently raises PUE and compounds energy costs. Spin Klin™ discs consistently deliver a filtrate clogging ratio well above the ISO 18471 minimum, while competitor discs fall short at both 55μm and 100μm. This gives data-center operators confidence that cooling-water quality is controlled to maintain thermal stability, reduce maintenance, and support.

Filtrate clogging ratio Spin Klin™ vs. other discs

16
3
55μm
15
3
100μm
ISO 18471 minimum (ratio = 5)
Spin Klin™ discs
Other discs

This graph shows the inlet/outlet clogging time ratio of the Spin Klin™ discs compared to other discs, in tests performed with 55 & 100 micron discs.

Disc Filtration is Ideal for Data Center Cooling Towers

It delivers the widest filtration range, lowest water use, smallest footprint, and the highest fouling control — at the lowest OPEX. DATA Klin disc systems outperform sand, media, and separator alternatives on every dimension that matters for mission-critical uptime.

ParametersDiscMediaSand Separators
Filtration degree (μ)10-40010-130*70-150
Water useLowHighLow
AutomaticYesYesYes
FootprintSmallLargeSmall
Fouling controlHighMediumHigh
OPEXLowHighLow

* Depends on filter-bed type, depth, filtration area and raw water quality

Ready to KeepData Flowing?

Contact our cooling tower filtration experts

Frequently Asked Questions.

Everything you need to know before specifying a DATA Klin system.

Why Choose Amiad

Amiad has been protecting industrial water systems for over 60 years. Our DATA Klin series brings that expertise directly to data center cooling - with the only self-cleaning disc filtration system purpose-built for mission-critical cooling towers.

From a single edge site to a 500 MW hyperscale campus, we size, specify, and support every system - ensuring the right solution is implemented correctly and backed by long-term support.

Proven Expertise

60+ years as a world leader in industrial water filtration - with ISO 18471-verified, standard-compliant technology proven across thousands of sites globally.

End-to-End Support

From sizing and specification through installation, commissioning, and long-term service - one partner throughout. Our engineers analyse your flow rate, TSS profile, and site constraints before recommending a single product.

Global Footprint

6 production sites, 11 subsidiaries across 5 continents - local expertise wherever your data centers operate.

Standards & Certifications

ISO 18471-verified filtration performance across the full declared micron range. Products designed to meet ASHRAE and data center industry standards.